Basic Info
|
|||
Model No.
|
CSI-7K/9K-S22003-E
|
||
Output Power
|
>1000W
|
||
Grid Type
|
Grid Inverter
|
||
Output Type
|
Triple
|
||
Circuit Topologies
|
Push-Pull Type
|
||
Nature Of Wave String
|
Sine Wave Inverter
|
||
Type
|
DC/AC Inverters
|
||
Power Range
|
5KW-10KW
|
||
Transport Package
|
Cartons And Pallet
|
||
Trademark
|
CanadianSolar
|
||
Origin
|
Nanjing, Jiangsu, China
|
||
Production Capacity
|
5000 Sets/Year
|
System Technical Data | |||
Model Name | CSI-7K-S22003-E | CSI-9K-S22003-E | |
DC Input | |||
Max. DC Input Voltage (V) | 600 | ||
Start-Up DC Input Voltage (V) | 110 | ||
MPPT Operating Voltage Range (V) | 100-500 | ||
Rated Input Voltage (V) | 360 | ||
Max. Input Current (A) | 15/30 | ||
Max. Short-Circuit Current (A) | 18.8/37.6 | ||
Number Of MPP Trackers | 2 | ||
Number Of DC Inputs | 1/2 | ||
AC Output | |||
Rated Output Power (W) | 7000 | 9000 | |
Max. Output Power (W) | 7000 | 9000 | |
AC Grid Connection Type | L/N/PE | ||
AC Nominal Voltage And Range (V) | 220/230/240 (180-280) | ||
AC Nominal Frequency And Range (Hz) | 50/60 (+5) | ||
Max. Output Current (A) | 31.8 | 40.9 | |
Displacement Power Factor | 0.8 Leading To 0.8 Lagging | ||
Total Harmonic Distortion (THDI) | <3% | ||
Efficiency | |||
Max. Efficiency | 98.1% | ||
European Efficiency | 97.5% | ||
Safety & Protection | |||
DC Switch | Integrated | ||
Anti-Islanding Protection | Integrated | ||
DC Reverse-Polarity Protection | Integrated | ||
Insulation Monitoring | Integrated | ||
AC Over Voltage Protection | Integrated | ||
AC Over Current Protection | Integrated | ||
AC Short-Circuit Protection | Integrated | ||
Residual Current Protection | Integrated | ||
Overvoltage Class | II(DC),III(AC) | ||
General Parameters | |||
Dimensions (WxHxD, mm) | 355 x 435 x 158 | ||
Net Weight (kg) | 13.5 | ||
Installation Method | Wall-mounted | ||
DC Connection Type | MC4, T6 | ||
AC Connection Type | Connector | ||
Communication Interfaces | WIFI/RS485 | ||
Display | LED+APP | ||
Cooling | Natural Convection | ||
Protection Degree | IP65 | ||
Operating Ambient Temperature Range (°C) | -25-60 (>45, derating operation) | ||
Relative Humidity (Non-Condensing) | 0 %-100% | ||
Max. Operating Altitude (m) | 4000 (> 3000, derating operation) | ||
Acoustic Noise Emission Level (dBA) | < 25 | ||
Topology | Transformerless | ||
Night Power Consumption (W) | <1 | ||
Safety and EMC | IEC 62109-1/2, IEC 61000-6-1, IEC 61000-6-3 | ||
Grid Connection Standard | ABNT NBR 16149/16150:2013 |