Nitrox Hybrid 12KW 2024 Model

Key Features
  • 100% unbalanced output, each phase; Max.output up to 50% rated power
  • Max. 10 pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
  • AC couple to retrofit existing solar system
  • Max. charging/discharging current of 240A
  • 6 time periods for battery charging/discharging
  • 48V low voltage battery, transformer isolation design
  • Support storing energy from diesel generator
Categories : , Brand:

Additional information

Mechanical Parameters
Model Nitrox 12KW
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 240
Max. Discharging Current (A) 240
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. DC Input Power (W) 15600
Max. DC Input Voltage (V) 800
Start-up Voltage (V) 160
MPPT Voltage Range (V) 100-650
Rated DC Input Voltage (V) 550
Max. Operating PV Input Current (A) 20+20
Max. Input Short-Circuit Current (A) 30+30
No. of MPP Trackers/No. of Strings per MPP Tracker 2/1+1
AC Input/Output Data
Rated AC Input/Output Active Power (W) 12000
Max. AC Input/Output Apparent Power (VA) 13200
Rated AC Input/Output Current (A) 18.2/17.4
Max. AC Input/Output Current (A) 20/19.2
Max. Three-phase Unbalanced Output Current (A) 27.3/26.1
Max. Continuous AC Passthrough (grid to load) (A) 45
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range (Hz) 50/45-55, 60/55-65
Grid Connection Form L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 97.0%
MPPT Efficiency >99%
Equipment Protection
Integrated DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection,
DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring,
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
Overvoltage Load Drop Protection, Residual Current Detection (RCD), Surge Protection Level
Surge Protection Level TYPE II (DC), TYPE II (AC)
Interface
Communication Interface WIFI, RS485, CAN
General Data
Operating Temperature Range (°C) -40 to +60°C , >45°C Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 3000m
Noise (dB) 55
Ingress Protection (IP) Rating IP 65
Inverter Topology Non-isolated
Over Voltage Category OVC II (DC), OVC III (AC)
Cabinet Size (WxHxD mm) 366×589.5×237 (Excluding Connectors and Brackets)
Weight (kg) 35.5
Type of Cooling Intelligent Air Cooling
Warranty 5 Years
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

Please fill out below form for product Query