Nitrox Hybrid 8KW 2024 Model

Key Features
  • Colorful touch LCD, IP65 protection degree
  • AC couple to retrofit existing solar system
  • Max. 16 pcs parallel for on-grid and off-grid DUAL MPPT operation; Support multiple batteries parallel
  • Max. charging/discharging current of 190A
  • 6 time periods for battery charging/discharging
  • Support storing energy from diesel generator
Categories : , Brand:

Additional information

Mechanical Parameters
ModelNitrox 8KW
Battery Input Data
Battery TypeLead-acid or Lithium-ion
Battery Voltage Range (V)40-60
Max. Charging Current (A)190
Max. Discharging Current (A)190
Charging Strategy for Li-ion BatterySelf-adaption to BMS
Number of Battery Input1
PV String Input Data
Max. DC Input Power (W)10400
Max. DC Input Voltage (V)500
Start-up Voltage (V)125
MPPT Voltage Range (V)150-425
Rated DC Input Voltage (V)370
Max. Operating PV Input Current (A)26+26
Max. Input Short-Circuit Current (A)34+34
No. of MPP Trackers/No. of Strings per MPP Tracker2/2
AC Input/Output Data
Rated AC Input/Output Active Power (W)8000
Max. AC Input/Output Apparent Power (VA)8800
Rated AC Input/Output Current (A)36.4/34.8
Max. AC Input/Output Current (A)40/38.3
Max. Continuous AC Passthrough (grid to load) (A)50
Peak Power (off-grid) (W)2 times of rated power, 10s
Power Factor Adjustment Range0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V)220/230 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range (Hz)50/45-55, 60/55-65
Grid Connection FormL+N+PE
Total Current Harmonic Distortion THDi<3% (of nominal power)
DC Injection Current<0.5% In
Efficiency
Max. Efficiency97.6%
Euro Efficiency96.5%
MPPT Efficiency>99%
Equipment Protection
IntegratedDC Polarity Reverse Connection Protection, AC Output Overcurrent Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, Thermal Protection,
DC Terminal Insulation Impedance Monitoring, DC Component Monitoring, Ground Fault Current Monitoring,
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
Overvoltage Load Drop Protection, Residual Current Detection (RCD), Surge Protection Level
Surge Protection LevelTYPE II (DC), TYPE II (AC)
Interface
Communication InterfaceWIFI, RS485, CAN
General Data
Operating Temperature Range (°C)-40 to +60°C , >45°C Derating
Permissible Ambient Humidity0-100%
Permissible Altitude2000m
Noise (dB)<30
Ingress Protection (IP) RatingIP 65
Inverter TopologyNon-isolated
Over Voltage CategoryOVC II (DC), OVC III (AC)
Cabinet Size (WxHxD mm)366×589.5×237 (Excluding Connectors and Brackets)
Weight (kg)26.8
Type of CoolingIntelligent Air Cooling
Warranty5 Years
Grid RegulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety / EMC StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2